FlexDEC® 2K - en
FlexDEC® 2KEN
6150611464440
FlexDEC® 2K is a high-performance, solvent-free, two-component, polyurethane-based, self-levelling, flexible and seamless flooring resin developed exclusively for interior applications.
Formulated using advanced polyurethane technology, the product combines high tensile strength, tear resistance, excellent mechanical properties and crack-bridging capability with a flexible polymer structure, enabling the formation of durable, smooth and continuous flooring surfaces.
FlexDEC® 2K is developed for enclosed car parks, residential living areas, offices, showrooms, shopping centres, commercial premises, healthcare facilities and other suitable interior applications.
Its self-levelling characteristics facilitate the formation of smooth, uniform and seamless surfaces over appropriately prepared substrates. Its flexible polyurethane matrix contributes to accommodating limited substrate movement within the verified capabilities of the system and providing resistance to mechanical stresses arising under normal service conditions.
FlexDEC® 2K represents a high-technology self-levelling flooring solution developed within the ANILO® Integrated System. The product is engineered to function in combination with compatible ANILO® substrate primers, particularly EpoxyPRIMER 2K and Primer L-2K, selected according to substrate type, surface condition and technical requirements.
Appropriate substrate preparation and correct primer selection are essential for achieving reliable adhesion, consistent system performance and long-term flooring durability.
Mandatory Protective Topcoat: Following completion of the FlexDEC®-2K application and once the flooring has reached the required curing condition, TopcoatDEC SF-2K must be applied to enhance surface resistance to scratching, abrasion and service-related wear, and to provide additional protection against surface deterioration caused by UV radiation.
TopcoatDEC SF-2K must be applied in accordance with the conditions specified in its relevant technical data sheet.
Important: FlexDEC® 2K is developed exclusively for interior applications. It is not suitable for outdoor use, areas directly exposed to weather conditions or open-air applications. The application of a protective topcoat does not change this limitation.
- Important Features
- High-performance, two-component, polyurethane-based self-levelling flooring resin developed exclusively for interior applications.
- Solvent-free formulation.
- Flexible, seamless and continuous flooring structure.
- High tensile strength and tear resistance.
- Advanced crack-bridging capability.
- High mechanical resistance and long-term service performance.
- Smooth and uniform surface formation through self-levelling properties.
- System structure designed for enclosed car parks, living areas, offices and suitable commercial interiors.
- System compatibility with EpoxyPRIMER 2K or Primer L-2K on suitable substrates.
- Formulation developed for use within the ANILO® Integrated Flooring System.
- Mandatory application of TopcoatDEC SF-2K as a protective topcoat for additional resistance to scratching, abrasion and UV-related effects.
- Suitable exclusively for interior applications; not suitable for outdoor use.
FlexDEC® 2K - en
FlexDEC® 2KEN
-
Advanced Flexible Polyurethane Technology:
The two-component reactive polyurethane formulation provides high tensile strength, tear resistance and flexibility, forming a durable flooring matrix under the intended interior service conditions. -
Self-Levelling, Seamless Surface:
Its self-levelling characteristics facilitate the formation of smooth, uniform and continuous surfaces over appropriately prepared substrates. -
High Mechanical Performance:
The cured polyurethane structure provides advanced mechanical properties that contribute to flooring durability under specified service loads and mechanical stresses. -
Crack-Bridging Capability:
The flexible polymer structure helps accommodate limited substrate movement within the verified performance limits of the system. -
Chemical Resistance:
Following complete curing, the product provides resistance to compatible chemical exposures, depending on the type, concentration, temperature and duration of contact with the chemical substance. -
Temperature Resistance:
The existing technical documentation specifies service temperature resistance from −40°C to +80°C, with short-term thermal shock resistance up to 200°C. These values represent the technical performance of the material under the relevant test conditions. They do not indicate that the product is suitable for outdoor applications. -
ANILO® Integrated System Compatibility:
FlexDEC® 2K is designed as part of an integrated flooring system comprising appropriate substrate preparation, application of EpoxyPRIMER 2K or Primer L-2K, and completion with the TopcoatDEC SF-2K protective topcoat. -
Mandatory Protective Topcoat:
Following the application of FlexDEC® 2K, TopcoatDEC SF-2K must be applied. This finishing layer is specified as a complementary system component to enhance surface resistance to scratching, abrasion and service-related wear, while providing additional protection against UV-related surface deterioration. -
Interior Applications Only:
The product is developed for enclosed interior flooring applications. It must not be used outdoors or in areas directly exposed to weather conditions.
FlexDEC® 2K is developed for use in the following suitable interior flooring applications:
- Enclosed car parks and indoor parking facilities
- Residential and living areas
- Offices and administrative buildings
- Showrooms and exhibition areas
- Shops and commercial premises
- Shopping centres and supermarkets
- Hotels and accommodation facilities
- Hospitals and healthcare facilities
- Educational institutions and public buildings
- Suitable enclosed industrial production areas
- Food and beverage production facilities complying with the relevant system requirements
- Other suitable interior areas requiring flexible, seamless and mechanically resistant flooring systems
Important: The suitability of each application area must be assessed according to substrate characteristics, anticipated mechanical loads, traffic intensity, chemical exposure, moisture conditions and the approved ANILO® system specifications.
FlexDEC® 2K is not suitable for outdoor applications.
Indicative Consumption:
Approximately 1.3 kg/m² for an application thickness of 1 mm.
Actual consumption may vary depending on substrate evenness, surface condition, application thickness and application losses.
The approved mixing ratio of the components by weight must be verified before application.
FlexDEC® 2K - en
FlexDEC® 2KEN
Substrate Preparation:
The substrate must be sound, stable, clean, dry and free from all contaminants that could adversely affect the adhesion of the flooring system. The surface must be free from dust, cement laitance, oil, grease, loose particles, weak coatings and other substances that could impair adhesion. Concrete surfaces must be prepared using suitable grinding, shot-blasting or equivalent mechanical preparation methods. Cracks, joints, surface defects and areas with insufficient strength must be assessed before application and repaired using suitable repair materials.
The existing TDS specifies an approximate concrete strength of R28 = 15 MPa, relative humidity below 80% and substrate moisture below 10%. These values must be assessed together with the technical requirements of the selected primer.
Primer Application:
A suitable ANILO® substrate primer must be applied before FlexDEC® 2K installation. Depending on substrate type, porosity, moisture condition and adhesion requirements, EpoxyPRIMER 2K or Primer L-2K may be selected. Primer selection must comply with the relevant product technical data sheet and the approved system specification. The primer must be applied uniformly at the specified consumption rate. The required curing and overcoating intervals must be observed before proceeding with FlexDEC® 2K application. The components must be prepared according to the mixing ratio by weight approved by the manufacturer.
Components A and B must be mixed using a low-speed electric mixer operating at approximately 300 rpm until a homogeneous mixture is obtained. The prepared mixture must be applied within the specified pot life.
Application of the Self-Levelling Flooring Layer:
The prepared FlexDEC® 2K mixture must be poured onto the appropriately primed substrate. The material must be distributed uniformly to the required thickness using a suitable notched trowel, squeegee or similar application equipment. The existing TDS specifies an approximate application thickness of 1–10 mm. The application thickness must be determined according to anticipated service loads, substrate characteristics and the approved system specification.
De-Aeration:
Immediately after the material has been spread over the surface, a suitable spiked roller must be used to release entrapped air from the mixture. This procedure must be completed within the available working time of the material. The use of a spiked roller contributes to the formation of a smooth and uniform surface.
Curing and Surface Protection:
The freshly applied flooring must be protected against water, dust, contamination, premature pedestrian traffic and mechanical damage throughout the curing period.
The first page of the existing TDS specifies the following approximate times at 25°C:
Pot life: 30 minutes
Touch-dry time: 8 hours
Walkable after: 18 hours
Light traffic: 24 hours
Heavy traffic: 3–4 days
Actual curing times may vary depending on temperature, relative humidity, application thickness and environmental conditions.
The required curing conditions must be achieved before proceeding with subsequent application stages.
Mandatory Protective Topcoat — TopcoatDEC SF-2K
Following FlexDEC® 2K application, TopcoatDEC SF-2K must be applied as a protective finishing layer once the flooring has reached the required curing condition.
TopcoatDEC SF-2K is specified as the complementary protective layer of the ANILO® Integrated Flooring System.
The objectives of applying this protective topcoat are:
To enhance surface resistance to scratching.
To provide additional protection against abrasion and service-related wear.
To support the long-term surface performance of the flooring system.
To provide additional protection against surface deterioration caused by UV radiation.
To contribute to preserving the aesthetic appearance of the decorative flooring.
TopcoatDEC SF-2K must be applied in accordance with the surface preparation, mixing ratio, consumption, application method and curing conditions specified in its relevant technical data sheet.
Important: The application of TopcoatDEC SF-2K does not make FlexDEC® 2K suitable for outdoor use. The system is designed exclusively for interior applications.
Equipment Cleaning:
Application tools and equipment must be cleaned with a suitable cleaning solvent before the polyurethane material cures. The existing TDS specifies cellulosic thinner for equipment cleaning. The relevant safety instructions must be followed, and adequate ventilation must be provided during cleaning.
Application Limitations & Important Precautions
Interior Applications Only: FlexDEC® 2K is developed exclusively for self-levelling polyurethane flooring systems used in interior environments. It must not be applied outdoors or in areas directly exposed to atmospheric conditions.
UV Exposure: The FlexDEC® 2K surface must be protected with TopcoatDEC SF-2K against surface deterioration that may result from UV exposure. However, the application of a protective topcoat does not permit outdoor use of the product.
Mandatory Protective Topcoat: TopcoatDEC SF-2K must be applied to provide additional protection against scratching, abrasion, service-related wear and UV-related effects.
Correct Mixing: Incorrect component proportioning, insufficient mixing or application after the pot life has expired may adversely affect curing and the final flooring performance.
Application Conditions: Ambient temperature, relative humidity, substrate temperature and surface conditions must comply with the approved technical specifications.
Integrated System Performance: The long-term performance of the completed flooring system depends on appropriate substrate preparation, correct primer selection, proper FlexDEC® 2K application and correct application of the TopcoatDEC SF-2K protective topcoat.
FlexDEC® 2K - en
FlexDEC® 2KEN
Technical Specifications
| PROPERTY | UNITS | METHOD | SPECIFICATION |
|---|---|---|---|
| Pot life (20 °C & 55% RH) | Min. | internal | 20-30 |
| Viscosity (BROOKFIELD) upon mixing | cP | - | 5:1 |
| Specific weight | gr/cm³ | - | Component A (hardener): 1.20-1.30 Component B (resin): 1.25-1.35 |
| Tack free time, at 77°F (25°C) & 55% RH | hours | - | 2-3 |
| Service temperature | °C | - | -40 to 80 |
| Max. temperature short time (shock) | °C | - | 200 |
| Hardness | Shore D | - | > 60 |
| Tensile strength at break at 23 °C | (N/mm²) | - | > 13 |
| Percent elongation at 23 °C | % | - | > 70 |
| Abrasion Resistance (TABER) | Mg loss | - | 60 |
| Water vapor transmission | gr/m².hr | Water Method | 0.8 |